DIVISION 01 - GENERAL REQUIREMENTS
10 01 00 | Summary |
01 20 00 | Price and Payment Procedures (CFPUA Capital Projects) |
01 30 00 | Administrative Requirements (CFPUA Capital Projects) |
01 30 00 | Administrative Requirements (Development Projects) |
01 30 00 | Pre-Construction Checklist |
01 33 00 | Submittals (CFPUA Capital Projects) |
01 33 00 | Submittals (Development Projects) |
01 35 00 | Special Procedures |
01 40 00 | Quality Requirements |
01 50 00 | Temporary Facilities and Controls (CFPUA Capital Projects) |
01 51 00 | Bypass Pumping |
01 60 00 | Product Requirements |
01 70 00 | Execution and Closeout Requirements (CFPUA Capital Projects) |
01 70 00 | Execution and Closeout Requirements (Development Projects) |
01 78 39 | Project Design Drawing Requirements |
DIVISION 02 - EXISTING CONDITIONS
02 41 00 | Demolition |
02 82 13 | Asbestos Abatement for Utilities |
DIVISION 03 - CONCRETE
03 05 00 | Concrete |
03 40 01 | Precast Concrete Control Building |
DIVISION 05 - METALS
05 05 00 | Anchoring Systems |
05 50 00 | Metal Fabrications |
05 53 00 | Metal Gratings |
DIVISION 09 - FINISHES
09 91 00 | Painting and Protective Coatings |
DIVISION 10 - SPECIALTIES
10 14 00 | Signage |
DIVISION 26 - ELECTRICAL
26 05 02 | Basic Electrical Work |
26 05 36 | Cable Trays for Electrical Systems |
26 05 43 | Electrical Site Work |
26 20 05 | Electrical Distribution Equipment |
26 29 15 | Pump Control Panels |
26 29 23 | Low Voltage Variable Frequency Drivers |
26 32 13 | Standby Generator |
26 36 23 | Automatic Transfer Switches |
26 50 01 | LED Lighting |
DIVISION 31 - EARTHWORK
31 23 34.01 | Excavating, Trenching, Dewatering and Backfilling for Utility Work |
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 13 01 | Concrete Sidewalks, Driveways, and Gutters |
32 31 00 | Security Fencing (Chain Link) |
32 31 19 | Security Fencing (Decorative) |
32 92 01 | Seeding and Sodding |
DIVISION 33 - UTILITIES
33 01 12 | Identification for Utilities Piping |
33 01 30.86 | Manhole Rim Adjustment |
33 05 05.31 | Hydrostatic Testing |
33 05 07.13 | Utility Horizontal Directional Drilling |
33 05 07.23 | Jacking and Boring |
33 05 09.33 | Thrust Restraint for Utility Piping |
33 05 13 | Precast Concrete Manholes and Utility Structures |
33 14 13 | Water Distribution Piping, Valves, Hydrants and Appurtenances |
33 14 14 | Public Water Service Connections |
33 14 20 | Disinfection of Water Pipelines, Facilities and Appurtenances |
33 14 22 | Testing of Sanitary Sewer Mains and Manholes |
33 31 11 | Sanitary Sewer Gravity Mains |
33 31 23 | Sanitary Sewer Force Mains, Valves and Appurtenances |
33 32 15 | Wastewater Pump Station Startup |
33 32 17 | Low Pressure Sewer Systems and Residential Grinder Pump Stations |
33 32 18 | Commercial Grinder Pump Systems |
DIVISION 40 - PROCESS INTERCONNECTIONS
40 71 00 | Magnetic Flow Meters |
40 78 00 | Panel Mounted Instruments and Devices |
40 95 01 | Wastewater Pump Station SCADA Remote Telemetry Unit (RTU) |
43 21 39 | Submersible End Suction Pumps |